Illustrate
TDS-100H series ultrasonic flow meter is widely used to measure liquid flow in various industries
Brief Introduction
- Designed according to Europe alliance EN1434 standard and ultrasonic time-difference principle.
- Ultrasonic time-difference principle Measuring water or other liquid.
- High accuracy, better reliable, no moving part, no need to set data. Install in any angle.
- It can instead of other water meter
Main Features
- Accuracy: ±1%,± 2%,Repeatability: ±0.5%.
- Measurement cycle: Default for 3S, 1~31S should be optional by the user.
- Battery can work 6-10years, or two line power.
- Lowest measuring velocity of liquid 0.01m/s
- No pressure lost and moving parts, no nursing for 10 years
- Pipe length designing according to the normal water meter
- IP68, can working under water lower than 2 meters
- Foundry in mould, no leakage
- Ceramic sensor apply to -40℃~160℃
- Over look type, normal type, separate type
Technical Paramters
Pipe ID (mm) |
Lowest Flowrate Detectable |
Min.Flowrate qmin |
Boundary Flowrate qt |
Max.Flowrate qmax |
Cumulative Flowrate (m3) |
||
(m3/h) | Max | Min | |||||
15 | 0.0019 | 0.0238 | 0.072 | 1.5 | 99999.999 | 0.001 | |
20 | 0.0019 | 0.0238 | 0.072 | 2.5 | |||
25 | 0.0045 | 0.056 | 0.169 | 3.0 | |||
32 | 0.0073 | 0.092 | 0.275 | 12 | |||
40 | 0.0114 | 0.144 | 0.429 | 20 | |||
50 | 0.0353 | 0.35 | 2.1 | 150 | 9999999.9 | 0.1 | |
65 | 0.06 | 0.60 | 3.58 | 180 | |||
80 | Single-path | 0.09 | 0.9 | 5.43 | 230 | ||
Double-path | 0.063 | 0.9 | 5.43 | 230 | |||
100 | Single-path | 0.141 | 1.41 | 8.48 | 300 | ||
Double-path | 0.099 | 1.41 | 8.48 | 300 | |||
125 | Single-path | 0.221 | 2.21 | 13.25 | 360 | ||
Double-path | 0.155 | 2.21 | 13.25 | 360 | |||
150 | Single-path | 0.318 | 3.18 | 19.08 | 460 | ||
Double-path | 0.223 | 3.18 | 19.08 | 460 | |||
200 | Single-path | 0.565 | 5.6 | 33.93 | 660 | ||
Double-path | 0.396 | 5.6 | 33.93 | 660 | |||
4-path | 0.226 | 5.6 | 33.93 | 660 | |||
250 | Single-path | 0.883 | 8.83 | 53.0 | 740 |