AK Gas Roots Flow Meter

Illustrate

AK gas roots flowmeter can be used to measure air , natural gas ,biogas gas

Working Principle

AK series gas roots flowmeter is mainly composed of components such as shell,conjugate rotor and counting device etc. A pair of conjugate rotors installed inside the measuring room kept at the correct relative position through precision-machined adjusting gear under the action of pressure difference (Pinlet>Poutlet) between outlet and inlet of circulating air. Continuous noncontact seal is realized by the best working clearance between rotors, rotor and shell, rotor and wallboard. Each time the rotor rotates, it will output gas four times of

the effective volume of measuring room. The revolution of rotor is transmitted to integrating indicator counter through magnetic seal coupling device and reduction mechanism, thus indicating the accumulative volume of gas outputted. The measuring process and working principle are shown in Figure 1 (only a quarter of one cycle is shown).

Main Technical Parameters

Error of flow meter
LLQ series gas roots flowmeter has the typical error curve and pressure loss curve of volumetric air flowmeter, 
refer to the figure below for details:

Measuring Range
Flow Range Table of CX Series Gas Roots Flowmeter

Nominal
Diameter
(mm)
Model Starting
Flow
m3/h
Flow Range
m3/h
Maximum
Pressure
Loss
Pa
Range
Ratio

 
Pressure
Grade
MPa
Accuracy
%
Material
50 LLQ-50A 0.05 1.00~20.00 80 20:1 1.0 1.0, 1.5 Aluminum
LLQ-50B 0.07 1.25~25.00 80 20:1 1.0 1.0, 1.5 Aluminum
LLQ-50C 0.07 1.33~40.00 100 30:1 1.0 1.0, 1.5 Aluminum
LLQ-50D 0.07 1.00~60.00 140 60:1 1.0 1.0, 1.5 Aluminum
LLQ-50E 0.07 1.21~85.00 200 70:1 1.0 1.0, 1.5 Aluminum
80 LLQ-80A 0.07 1.43~100.00 150 70:1 1.0 1.0, 1.5 Aluminum
LLQ-80B 0.08 1.17~140.00 220 120:1 1.0 1.0, 1.5 Aluminum
LLQ-80C 0.15 2.86~200.00 230 70:1 1.0 1.0, 1.5 Aluminum
80 LLQ-100A 0.11 3.13~250.00 300 80:1 1.0 1.0, 1.5 Aluminum
LLQ-100B 0.11 2.73~300.00 350 110:1 1.0 1.0, 1.5 Aluminum
LLQ-100C 0.11 4.09~450.00 450 110:1 1.0 1.0, 1.5 Aluminum
LLQ-100D 0.11 5.55~500.00 550 110:1 1.0 1.0, 1.5 Aluminum
150 LLQ-150A .0.65 8.13~650.00 450 80:1 1.0 1.0, 1.5 Aluminum
LLQ-150B 0.76 10.00~800.00 500 80:1 1.0 1.0, 1.5 Aluminum
LLQ-150C 0.76 12.50~1000.00 600 80:1 1.0 1.0, 1.5 Aluminum
LLQ-150D 0.76 13.33~1200.00 700 90:1 1.0 1.0, 1.5 Aluminum
200 LLQ-200A 1.15 30.19~1600.00 650 53:1 1.0 1.0, 1.5 Aluminum
Model Selection, Installation & Operation Maintenance of Flowmeter
 
 
1. Model of Product
CX-□-□-□-□-□
                     ① ② ③ ④ ⑤
 
Description
 Nominal diameter (mm) and flow range: If complete with 50 A means the caliber is 50 mm, the flow range is
 1~20 m3/h. Please refer to the model in Flow Range Table for specific completion.

 Complete I with chemical gauge head (conventional); complete II with totalizer gauge 
  head (intelligent); complete III with double gauge heads.

 Complete I0 with current output; complete N with N/A.

 Complete R4 with RS485 communication; complete R2 with RS232C

communication; complete RM with standard MODBUS protocol; complete RH with standard HART protocol;
 complete N with N/A. 
 Complete IC with quantitation pulse output of IC card; complete N with N/A
 Complete maximum working pressure (e.g. 1.6 MPa).